Acquiring the proper fiber optic cables for a customer to connect equipment can be a very easy process. We stock a variety of lengths with different connectivity options that include standard connectors like LC, SC and ST. How difficult is it, though, if the fiber optic cable needs to be 1 kilometer long to connect to another building, will be buried outside to avoid the elements and also needs shielding to protect it from being severed? Easier then you might think. Anytime a customer is looking for a fiber optic cable with more than two fibers, longer than 30 meters or being installed in an environment other than a data center or communications closet the chances are a custom fiber solution will be needed.Fiber Testers: What You Need to Know before you buy!
Whether its outside plant (OSP) infrastructure, links between equipment in the data center, or the backbone in a LAN, a light source and power meter (LSPM) test set is the most vital of all tools for testing an installed fiber plant. Most specifications require Tier 1 testing per TIA and ISO standards using an LSPM to calculate total insertion loss and length. And even if a specification calls for Tier 2 testing, which requires an
optical time domain reflectometer (OTDR) for determining insertion loss and reflection of individual connection points, final insertion loss testing still needs to be done with an LSPM test set that provides the most accurate overall channel loss testing.
Why do you need to test insertion loss and length with an LSPM test set? Insertion loss is the amount of energy that a signal loses over the length of a fiber link. It is directly related to the length of the links and also caused by any connection points along the link (i.e., connectors and splices). Specific fiber applications have a maximum channel insertion loss and length, and if the loss is too high, the signal cannot be properly interpreted by active equipment and the link will not function. Thats a pretty big deal when you consider that fiber links are the foundation of all networks.
When choosing an LSPM test set for your fiber testing, there are certain key features and specifications you need to know to make sure you can accurately, efficiently, and cost-effectively test installed fiber links for your projects.
Glass, Wavelengths, and Detectors Matter
When choosing an LSPM test set, you first need to know the type of fiber you need to testmultimode or singlemode. There are some LSPM test sets that may only test one type of fiber or the other, but ideally you want to choose one with the capability to test both multimode and singlemode. Its pretty rare that you will only install one type of fiber for all your projects.
You also need to know what wavelengths your application requires and check your tester specifications to ensure they are supported by the light source. Most multimode applications operate at the 850-nanometer (nm) wavelength, but there are some multimode applications like BiDi and 400GBASE-SR4.2 that use wave division multiplexing (WDM) technology and also operate in the 900 nm to nm range. The most common wavelengths for singlemode
Recommended article:How MPO Patch Panels Revolutionize Network Connectivity?
Wirenet Product Page
applications are and nm, but some WDM-based applications will operate at additional wavelengths between and nm. For example, 10 Gig passive optical network (PON) applications operate at and nm wavelengths, while 1 Gig PON operates at and nm wavelengths. For Wavelength Division Multiplexing (WDM) systems applications, you want a power meter that can quickly check loss on each wavelength.
One key factor when determining which fiber type and wavelengths are supported by an LSPM test set is the type of detector the power meter uses for measuring loss. A silicon detector type (abbreviated as Si) is really only suitable for multimode fiber for wavelengths to 850 nm, while a germanium detector (abbreviated as Ge) can effectively measure both multimode and singlemode wavelengths from 600 to nm. A indium gallium arsenide detector (abbreviated as InGaAs) is the highest power option that is ideally suited for high-power, long-haul ER and LR singlemode applications. Power meters that use Ge detectors are ideal for the majority of installers needing to test multimode and singlemode fiber links in premise LANs and data centers.
Consider Connector Types
When it comes to choosing an LSPM test set, you also need to consider connector type. Many testers will include interchangeable adapters to support SC, ST, and FC connectors with a 2.5 mm ferrule and LC connectors with a 1.5 mm ferrule. If your cable plant uses angled polish contact (APC) connectors, you want to make sure that these connectors are supported.
If your network uses multi-fiber connectivity such as an MPO/MTP connector for parallel optic applications, you will want a power meter that features an MPO/MTP interface with the ability to test all fibers simultaneously. Testing MPO/MTP-based applications with a duplex tester is extremely time consuming and complex, requiring breakout test leads and testing one pair at a time. Some power meters will support only 12-fiber MPO/MTPs while others will support 12-fiber, 16-fiber, and even 32-fiber MPOs/MTPs.
Saving with the Whole Kit and Kaboodle
While light sources, power meters, and associated test leads and adapters can be purchased separately, it doesnt do you much good if you dont have it all. Plus, when it comes to testing fiber, it isnt just test with an LSPM test set and youre done. Cleaning and inspecting fiber connectors is a vital part of the process. In fact, its recommended to clean, inspect, and then test. Its also helpful to have a visual fault locator (VFL) on hand for when you need to troubleshoot your fiber network.
Unless youre replacing individual components, its ALWAYS more cost effective to go with a full kit that includes everything you need to test multimode and singlemode fiber for all your installslight source, power meter, interchangeable adapters for different connector types, inspection microscope, cleaning tools and materials, and a VFL. Plus, a kit makes its easy to carry everything you need into the field in one protective case.
The good news is that Cables Plus offers a comprehensive line of fiber test equipment for all your fiber network testing applicationsTelco, FTTX, data center, LAN or WANincluding a complete line of light source and power meter fiber test kits. We can help you find the right test equipment to suit your needs and budget. Just contact us at .